Abstract

Greensand filtration is a common treatment option for manganese, sulfide, and iron removal; poor maintenance, however, can compromise effectiveness and even lead to increased post-treatment Mn concentrations. A private drinking-water well in exceedance of Health Canada’s maximum allowable concentration for Mn was sampled over a 1-year period to assess Mn removal via greensand filtration. Mn concentrations post-treatment were on average twofold higher than raw well water prior to media change. Reducing conditions, evidenced by negative oxidation–reduction potential (ORP) of the effluent, were central to generating soluble Mn(II). Monitoring revealed that water usage patterns caused variability in post-treatment Mn, with peak concentrations (>3.5× higher than influent water) observed after a 7-day idle period. As inadequate oxidant addition can lead to reducing conditions, monitoring ORP may facilitate proxy surveillance for Mn release. Findings underscore the importance of human factors (e.g., aesthetic concerns, barriers to maintenance, perceived risk) when evaluating overall benefits and drawbacks of treatment systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.