Abstract

Swept source optical coherence tomography (SS-OCT) is an interferometric imaging technique. This study aimed to assess SS-OCT as a diagnostic tool for the evaluation of occlusal fissure depth and sealant penetration into fissure. Seventy investigation sites of occlusal fissures without visible evidence of caries were categorized into four groups (smooth, shallow, intermediate, and deep fissures). Categorization utilized two methods: 1) visually, using a computer screen, and 2) using SS-OCT images. After sealant placement, penetration was observed in SS-OCT. The results obtained from SS-OCT and visual inspections were compared with those of confocal laser scanning microscope (CLSM). The diagnostic power of SS-OCT was higher than that of visual inspection for fissure depth. Additionally, clear cross-sectional images of sealant penetration into fissures were observed with SS-OCT. SS-OCT can be used to evaluate fissure depth and monitor sealant penetration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.