Abstract

In the simplified analysis of seismic design of gravity quay walls based on the pseudo-static approach, selection of an appropriate horizontal seismic coefficient (kh) is important for computing the equivalent pseudo-static inertial force. However, there is no unified standard for defining kh. There are conflicts among the existing kh definitions regarding whether it considers (a) the effect of wall height on maximum horizontal acceleration (MHA) used in the determination of kh or (b) the application of correction factor for kh according to seismic performance grade. This paper evaluates the relevance of these conflicts by initially reviewing the kh definitions in the existing codes and guidelines for port structures and then by performing a series of dynamic centrifuge tests on caisson gravity quay walls of different wall heights (5, 10 and 15 m). A review of the existing codes and guidelines has shown that the correction factor for kh should be specified according to the seismic performance grade for the economical design of quay walls. On the other hand, based on the centrifuge tests, it was found that the MHA used in kh calculation and the correction factor for considering seismic performance grade should reflect the effect of wall height.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call