Abstract

The TRIGA 2000 reactor is a nuclear installation which is operated at 1000 kW. Gamma and neutron radiation exposure will contribute to occupational doses that will be received by operators and other radiation workers. To maintain the safety of radiation workers, assessment of gamma and neutron radiation is needed in the TRIGA 2000 reactor. survey in the hall reactor using the RTD 30 and RadEye NL detectors. In addition to the direct measurement, calculations are also carried out with simulation data dose using Monte Carlo MCNPX for the calculation and followed by PHITS to get the graphical dose distribution of gamma and neutron. The study will focus on the assessment of the diffusion Gamma and neutron doses by doing the measurement and simulation data collect for the aim of the optimization of the Radiation protection policy in the reactor TRIGA 2000 Bandung. The result of the measurement is shown with graph in different power taken during the measurement and the simulation is the graphical distribution dose of gamma and neutron using PHITS code. A preventive dose reduction technique, worker and publics protection elaborate to optimise the Radiation protection program.