Abstract

The lack of reliable echocardiographic techniques to assess diastolic function in children is a major clinical limitation. Our aim was to develop and validate the intraventricular pressure difference (IVPD) calculation using blood speckle-tracking (BST) and investigate the method's potential role in the assessment of diastolic function in children. Blood speckle-tracking allows two-dimensional angle-independent blood flow velocity estimation. Blood speckle-tracking images of left ventricular (LV) inflow from the apical 4-chamber view in 138 controls, 10 patients with dilated cardiomyopathies (DCMs), and 21 patients with hypertrophic cardiomyopathies (HCMs)<18years of age were analyzed to study LV IVPD during early diastole. Reproducibility of the IVPD analysis was assessed, IVPD estimates from BST and color M mode were compared, and the validity of the BST-based IVPD calculations was tested in a computer flow model. Mean IVPD was significantly higher in controls (-2.28±0.62mm Hg) compared with in DCM (-1.21±0.39mm Hg, P<.001) and HCM (-1.57±0.47mm Hg, P<.001) patients. Feasibility was 88.3% in controls, 80% in DCM patients, and 90.4% in HCM patients. The peak relative negative pressure occurred earlier at the apex than at the base and preceded the peak E-wave LV filling velocity, indicating that it represents diastolic suction. Intraclass correlation coefficients for intra- and interobserver variability were 0.908 and 0.702, respectively. There was a nonsignificant mean difference of 0.15mm Hg between IVPD from BST and color M mode. Estimation from two-dimensional velocities revealed a difference in peak IVPD of 0.12mm Hg (6.6%) when simulated in a three-dimensional fluid mechanics model. Intraventricular pressure difference calculation from BST is highly feasible and provides information on diastolic suction and early filling in children with heart disease. Intraventricular pressure difference was significantly reduced in children with DCM and HCM compared with controls, indicating reduced early diastolic suction in these patient groups.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.