Abstract

The primary objective of this paper is to quantify the impact of the internal magnetic field and reversibility of the magnetocaloric effect on the numerical evaluation of the thermal performance of a parallel-plate active magnetic regenerator. To this end, direct measurements of the adiabatic temperature change of commercial-grade gadolinium samples were carried out for an applied field change of 1.65 ± 0.03 T (for both magnetization and demagnetization) and temperatures between 283 and 303 K. The tests were carried out in a specially constructed apparatus and the results were in good agreement with the literature. The data were incorporated into a mathematical model for solving the fluid flow and conjugated heat transfer in the parallel-plate regenerator. It was found that if demagnetization phenomena (i.e., the demagnetization factor and the reversibility of the magnetocaloric effect) are not take properly into account, the thermal performance of the regenerator can be severely over-predicted.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.