Abstract

Irradiation of the breast has shown to provide sharp dose gradients using Co-60 prone based stereotactic partial breast irradiation (CP-sPBI), a contemporary device for stereotactic radiotherapy for breast cancer (BC) for accelerated partial breast irradiation (APBI). In addition, the precise setup of CP-sPBI permits a small planning treatment volume (PTV) margin of 3 mm creating a greater distance from PTV to organs at risk. However, to date the factors that influence dose gradients and subsequent cardiac doses of ionizing radiation using CP-sPBI have not been well-studied. Here we evaluate distance of the heart to the lumpectomy PTV cavity and how this effects cardiac dose. A retrospective database of 113 consecutive patients treated by CP-sPBI for APBI from March 2019 to February 2023 who were treated with 30 Gy in 5 fractions were queried for analysis. The minimum distance from the heart to the PTV (hP) was measured in either the axial or sagittal view. A group of 28 patient cases were randomly selected to achieve an even distribution of 28 cases with hP < 2.75 cm and hP ≥ 2.75 cm to compare cardiac toxicities based on hP. Descriptive analyses were performed to evaluate various cardiac dosimetric parameters based on laterality of BC and hP, using the student's t test. The mean (range) hP was 4.58 cm (0.80-12.23) for all cases. The subgroup analyses of 28 patient cases with cardiac parameters showed the heart mean (range) dose of 1.20 Gy (0.01-2.11). The mean and max heart dose to the left-sided BC were similar to those to the right-sided BC (mean dose: 1.20 vs. 1.19 Gy; P = 0.97 and max dose: 10.47 vs. 5.66 Gy; P = 0.06). An inverse correlation between hP and mean heart dose was shown with the correlation coefficient of -0.81. Using a cutoff of 2.75 cm hP, the differences between hP < 2.75 and hP ≥ 2.75 cm for all cardiac dosimetric evaluations were all statistically significant, including mean (1.67 vs. 0.79 Gy; p<0.01) and maximal heart dose (14.48 vs. 4.11 Gy; p<0.01) CONCLUSION: CP-sPBI treatment delivery system was able to achieve acceptable clinically relevant heart dosimetric parameters when delivering 5 fraction APBI with a mean heart dose of 1.20 Gy for all locations of PTV cavity volume in the breast. Due to CP-sPBIs excellent dose fall-off characteristics, APBI using CP-SPBI showed clinically acceptable cardiac dosimetric parameters, particularly for PTVs located > 2.75 cm from the heart.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call