Abstract

Particle size is a critical parameter for controlling pharmaceutical quality. The aim of this study was to assess the size of the micrometer-scale active pharmaceutical ingredients (API) in tablets using Raman chemical imaging and to understand the effects of formulation on particle size. Model tablets containing National Institute of Standards and Technology traceable polystyrene microsphere size standards were developed to determine the binarization threshold value of Raman chemical images for API particle sizing in specific formulations and processes. Three sets of model tablets containing 5, 10, and 15 μm polystyrene microspheres, used to mimic API, were prepared using a commercial tablet formulation (Ebastel tablets, mean API particle size was about 5 μm). Raman mapping with a 50× objective (NA, 0.75) was applied to tablet cross-sections, and particle size of polystyrene microspheres was estimated from binary images using several binarization thresholds. Mean particle size for three sets of polystyrene microspheres showed good agreement between pre- and postformulation (the slope = 1.024, R = 1.000) at the specific threshold value ((mean + 0.5σ) of the polystyrene-specific peak intensity histogram), regardless of particle agglomeration, tablet surface roughness, and laser penetration depth. The binarization threshold value showed good applicability to Ebastel tablets, where the API-specific peak intensity histogram showed a pattern similar to that of polystyrene microspheres in model tablets. The model tablets enabled determination of an appropriate binarization threshold for assessing the mean particle size of micrometer-scale API in tablets by utilizing the unique physicochemical properties of polystyrene microspheres.

Highlights

  • The efficacy of pharmaceutical tablets depends on both the physical and chemical properties of the active pharmaceutical ingredient (API)

  • Determination of API particle size in the excipient matrix of the final product is a major challenge in pharmaceutical development

  • We investigated the use of Raman chemical imaging (CI) for sizing micrometer-scale API particles in a pharmaceutical tablet in order to better understand the effects of formulation on API particle size

Read more

Summary

Introduction

The efficacy of pharmaceutical tablets depends on both the physical and chemical properties of the active pharmaceutical ingredient (API). The size of ingredient particles is a critical process parameter for ensuring product quality. This size is determined by techniques such as microscopy and image analysis [4,5,6,7,8,9], sieving [5,9], laser diffraction [4,5,6,8,9,10,11], dynamic light scattering [4,5,7,12], electrical zone sensing (coulter counter) [4,5,8,10], time-of-flight measurements [4,6,11], and cascade impaction [4,13]. Determination of API particle size in the excipient matrix of the final product is a major challenge in pharmaceutical development

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call