Abstract

This study investigated the test-retest reliability and minimal detectable change (MDC) of muscle strength and physical performance tests in women older than 40 years. A total of 113 women, aged 58 ± 11 years (82% postmenopausal women), with a body mass index of 28.5 ± 5.8 kg/m 2 , participated in this study. One-repetition maximum (1RM) tests were conducted for seven strength exercises: 45° leg press, bench press, leg extension, pec deck, wide-grip lateral pull-down, leg curl, and seated cable row, with a retest after 48 hours. Timed Up and Go (TUG), 6-minute walk, and 30-second sit-to-stand tests were performed on the same day and retested after 72 hours. The tests and retests were administered by the same evaluators. Relative reliability (consistency of participant rank between test-retest) was assessed using the intraclass correlation coefficient for consistency and agreement, and absolute reliability (precision of score) was assessed using the MDC based on the standard error of prediction. The 1RM and performance tests exhibited excellent reliability: 45° leg press (consistency, 0.99; agreement, 0.98), bench press (consistency, 0.96; agreement, 0.96), leg extension (consistency, 0.93; agreement, 0.91), pec deck (consistency, 0.90; agreement, 0.88), wide-grip lateral pull-down (consistency, 0.91; agreement, 0.89), leg curl (consistency, 0.84; agreement, 0.83), seated cable row (consistency, 0.92; agreement, 0.94), TUG (consistency, 0.87; agreement, 0.87), 6-minute walk (consistency, 0.96; agreement, 0.95), and 30-second sit to stand (consistency, 0.85; agreement, 0.80). These tests showed meaningful MDC values, particularly for the 1RM test performed on the machine and the 30-second sit-to-stand test: 45° leg press, 22.2 kg (15%); bench press, 4.9 kg (19%); leg extension, 9.2 kg (35%); pec deck, 8.8 kg (44%); wide-grip lateral pull-down, 9.4 kg (31%); leg curl, 9.2 kg (51%); seated cable row, 11.4 kg (29%); TUG, 1.4 seconds (20%); 6-minute walk, 50.9 m (10%); and 30-second sit to stand, 4.6 reps (30%). Although the muscle strength and physical performance tests demonstrate excellent relative reliability in women older than 40 years, they exhibit low absolute reliability, particularly the 1RM test performed on the machine and the 30-second sit-to-stand test. Therefore, although these tests show good consistency in the positioning of women within the group after repeated measures, their precision measure is relatively low (high fluctuation). Changes in these tests that are smaller than the MDC may not indicate real changes in women at middle age and older.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.