Abstract
Current and future regulations regarding the exhaust gas system of automotive applications make the maximum exploitation of the Three-way catalytic converter's (TWC) performance mandatory. Furthermore, the on-board diagnosis (OBD) has to be able to monitor the performance of the TWC accurately. In order to gain deeper insight into the transient behaviour of a TWC, fast gas measurements of NO, HC, CO, CO2, O2 and H2 have been conducted and related to the response of different types of lambda sensors downstream of the TWC. Commercial type TWC's with three different levels of ageing have been used. Storage effects regarding oxygen and carbon monoxide, and the water-gas shift reaction can be interpreted from the measurements. Additionally, a method for the measurement of the oxygen storage capacity (OSC) is presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.