Abstract

Myringotomy and grommet insertion is one of the most common operations performed in Europe today, with an estimated 70,000 being carried out annually in Britain alone [Lancet 1 (1984) 835]. Otorrhoea is a common postoperative complication. There is controversy about the degree to which surgical asepsis should be maintained during the operation. This prospective study of 35 patients (70 ears) undergoing grommet insertion was carried out to evaluate the efficacy of two differing degrees of surgical asepsis. Using each patient as their own control a grommet was inserted into one ear with the surgeon wearing sterile gloves and masks, and the other wearing only clean non-sterile gloves. Discharge in the first 14 days occurred in five ears, three cases belonging to the former group and two to the latter. The results indicate that there is no significant difference in the incidence of postoperative otorrhoea using either of the above methods, and demonstrate that this operation may be performed in a safe but more cost efficient manner.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.