Abstract

Many new reconstruction techniques have been deployed to allow low-dose CT examinations. Such reconstruction techniques exhibit nonlinear properties, which strengthen the need for a task-based measure of image quality. The Hotelling observer (HO) is the optimal linear observer and provides a lower bound of the Bayesian ideal observer detection performance. However, its computational complexity impedes its widespread practical usage. To address this issue, we proposed a self-supervised learning (SSL)-based model observer to provide accurate estimates of HO performance in very low-dose chest CT images. Our approach involved a two-stage model combining a convolutional denoising auto-encoder (CDAE) for feature extraction and dimensionality reduction and a support vector machine for classification. To evaluate this approach, we conducted signal detection tasks employing chest CT images with different noise structures generated by computer-based simulations. We compared this approach with two supervised learning-based methods: a single-layer neural network (SLNN) and a convolutional neural network (CNN). The results showed that the CDAE-based model was able to achieve similar detection performance to the HO. In addition, it outperformed both SLNN and CNN when a reduced number of training images was considered. The proposed approach holds promise for optimizing low-dose CT protocols across scanner platforms.