Abstract

Objective: To explore the clinical value of four dimensional computed tomography (4 D CT) guided combined with deep inhalation and breath hold (DIBH) technique in the preoperative localization of solitary pulmonary nodules. Methods: The data of a total of 106 patients with solitary pulmonary nodules from March 2018 to May 2021 in the Ningbo First Hospital were collected retrospectively. Among them, there were 26 males and 80 females aged from 21 to 83 (47.4±14.2) years. According to different localization methods, 53 cases were divided into the control group, as the pulmonary nodules were located by CT guided injection of indocyanine green under calm breathing and 53 cases were divided into in the experimental group, as those patients were treated with indocyanine green injection under the guidance of 4 D CT combined with DIBH technology to locate pulmonary nodules. The three-dimensional distance deviation between pulmonary nodules and indocyanine green injection points was compared between the two groups to obtain the accuracy of pulmonary nodule localization. The preoperative positioning time of the two groups was compared by timing. Results: Among the 106 patients, there were 46 pure ground glass nodules, 32 sub solid nodules and 28 solid nodules, all of which were successfully localized before operation, with a success rate of 100%. The size of pulmonary nodules in the control group was (9.1±2.3) mm and the three-dimensional deviation[M(Q1, Q3)]between indocyanine green injection site and pulmonary nodules was X axis [7.0 (3.7, 12.6)] mm, Y axis [6.6 (2.9, 11.2)] mm, Z axis [3.0 (2.0, 6.0)]mm, respectively, and the preoperative positioning time was (11.4±3.8) min. The size of pulmonary nodules in the experimental group was (8.9±2.1) mm, and the deviations in 3 D direction were X axis [4.8 (3.0, 7.9)]mm, Y axis [3.8 (1.3, 7.5)]mm, Z axis [4.0 (2.0, 6.0)] mm, respectively. The preoperative positioning time was (9.3±3.0) min. There were statistically significant differences in preoperative positioning time and deviation of X and Y axis between the experimental group and the control group (P<0.05), but no statistically significant differences was found in deviation of Z axis (P>0.05). Conclusion: 4 D CT guided DIBH technology could improve the accuracy of preoperative localization of pulmonary nodules and save operation time, which is worthy of popularization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.