Abstract

The dynamic calibration method (DCM), using natural seismicity data and initially elaborated in [Kedrov, 2001; Kedrov et al., 2001; Kedrov and Kedrov, 2003], is applied to International Monitoring System (IMS) stations in Central Asia. The algorithm of the method is refined and a program is designed for calibrating diagnostic parameters (discriminants) that characterize a seismic source on the source-station traces. The DCM calibration of stations in relation to the region under study is performed by the choice of attenuation coefficients that adapt the diagnostic parameters to the conditions in a reference region. In this method, the stable Eurasia region is used as the latter. The calibration used numerical data samples taken from the archive of the International Data Centre (IDC) for the IMS stations MKAR, BVAR, EIL, ASF, and CMAR. In this paper, we used discriminants in the spectral and time domains that have the form $$ D_i = X_i - a_m m_b - b_\Delta \log \Delta $$ and are independent of the magnitude mb and the epicentral distance Δ; these discriminants were elaborated in [Kedrov et al., 1990; Kedrov and Lyuke, 1999] on the basis of a method used for identification of events at regional distances in Eurasia. Prerequisites of the DCM are the assumptions that the coefficient am is regionindependent and the coefficient bΔ depends only on the geotectonic characteristics of the medium and does not depend on the source type. Thus, bΔ can be evaluated only from a sample of earthquakes in the region studied; it is used for adapting the discriminants D(Xi) in the region studied to the reference region. The algorithm is constructed in such a way that corrected values of D(Xi) are calculated from the found values of the calibration coefficients bΔ, after which natural events in the region under study are selected by filtering. Empirical estimates of the filtering efficiency as a function of a station vary in a range of 95–100%. The DCM was independently tested using records obtained at the IRIS (Incorporated Research Institutions for Seismology) stations BRVK and MAKZ from explosions detonated in India on May 11, 1998, and Pakistan on May 28, 1998; these stations are similar in location and recording instrumentation characteristics to the IMS stations BVAR and MKAR. This test resulted in correct recognition of the source type and thereby directly confirmed the validity of the proposed calibration method of stations with the use of natural seismicity data. It is shown that the calibration coefficients bΔ for traces similar in the conditions of signal propagation (e.g., the traces from Iran to the stations EIL and ASF) are comparable for nearly all diagnostic parameters. We arrive at the conclusion that the method of dynamic calibration of stations using natural seismicity data in a region where no explosions were detonated can be significant for a rapid and inexpensive calibration of IMS stations. The DCM can also be used for recognition of industrial chemical explosions that are sometimes erroneously classified in regional catalogs as earthquakes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.