Abstract
In this study, we examined the safety and effectiveness of removing inferior vena cava (IVC) filters with residual acute thrombosis after endovascular therapy. A retrospective chart review of 712 patients who underwent retrievable IVC filter implantation between July 2018 and December 2022 was conducted. Residual thrombosis with the IVC filter occurred in 18 patients, and the volume of residual acute thrombosis in the IVC filter exceeded 1mL in all cases. Angiography was performed to evaluate the size of the residual thrombosis and its position with respect to the filter. The double series filter technique (first filter, infrarenal IVC filter; second filter, suprarenal IVC filter) was used to remove the filter and thrombosis. We summarize the diagnosis, treatment, and surgical experience of these patients. In this study, 16 of 18 patients (88.9%) demonstrated residual thrombosis in the IVC filter. One patient (5.6%) demonstrated thrombosis located both inside and floating above the filter, and one patient (5.6%) demonstrated thrombosis located both inside and underneath the filter. The technical success rate of double series IVC filter retrieval was 100%. Seventeen patients (94.4%) underwent single-stage suprarenal IVC filter retrieval, and one patient (5.6%, 1/18) underwent two-stage retrieval. In terms of residual thrombosis removal, 14 patients (77.7%) achieved complete removal and 4 patients (22.3%) achieved partial removal. Residual thrombosis could not be removed through the sheath in one patient, so femoral vein thrombectomy was performed. No other procedure-related complications were observed. The median follow-up time was 22.5±6.8months. No recurrence of thrombus symptoms was reported, and B ultrasound and computed tomography demonstrated smooth blood flow in the IVC, renal veins, and pulmonary artery. For patients with residual acute thrombosis on the IVC filter and in whom there was absence of a more appropriate treatment after percutaneous mechanical thrombectomy or catheter-directed thrombolysis therapy, the double series IVC filter technique was a safe approach to improve the IVC filter retrieval rate in the early stage, as well as for simultaneous residual thrombus removal.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.