Abstract
AbstractIn the work presented, a lead film electrode was prepared in situ on a screen-printed carbon support using a reversibly deposited mediator (Zn) and applied to the determination of Cd(II) by anodic stripping voltammetry. The electrochemical method for lead film formation is based on a co-deposition of a metal of interest (Pb), with a reversibly deposited zinc mediator, followed by oxidation of zinc, with additional deposition of lead at the appropriate potential. It serves to increase the density of lead particles, promoting lead film growth, and consequently helps to improve the electrochemical properties of the electrode. This was confirmed by microscopic and voltammetric studies. The obtained detection limit of Cd(II) is equal to 6.6 × 10−9mol L−1(−1.6 V for 180 s and then −0.95 V for 5 s). The presented procedure was successfully applied to cadmium determination in Bystrzyca River water samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.