Because of widely varying practices in solid waste management, an all-inclusive solution to long-term management of landfill leachate is currently not available. There is a major technological need for sustainable, economical options for safe discharge of leachate to the environment. Two potential on-site pretreatment technologies, photochemical iron-mediated aeration (PIMA) and TiO2 photocatalysis were compared for treatment of landfill leachate at laboratory scale. Results of bench scale testing of real landfill leachate with PIMA and TiO2 photocatalysis showed up to 86% conversion of refractory COD to complete mineralization, up to 91% removal of lead, up to 71% removal of ammonia without pH adjustment, and up to 90% effective color removal with detention times between 4 and 6h, in field samples. The estimated contact times for 90% removal of COD, ammonia, lead, and color were found to be on the order of 10–200h for PIMA and 3–37h for TiO2 photocatalysis. Testing with actual leachate samples showed 85% TiO2 photocatalyst recovery efficiency with no loss in performance after multiple (n>4 uses). Pre-filtration was not found to be necessary for effective treatment using either process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.