Abstract
In this paper a simple diagnostic method of a single IGBT open-circuit fault is presented, it is dedicated for three- phase two-level voltage-inverter-fed vector controlled induction motor drive systems. A failure diagnosis is based on a transient analysis of a reference voltage space vector in stationary coordinates, without additional sensors. The diagnostic algorithm ensures detection and localization of single IGBT failures in time shorter than one period of a stator current fundamental harmonic, without regard to a drive operation point. The presented scheme of the diagnostic system can be easily applicable in the electric drives that use voltage space vector modulation algorithms. The main achievement of the research, whose results have been presented in this paper, is an experimental validation of the analyzed IGBT faults diagnosis technique in the drive with the Direct Torque Control algorithm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Automatika ‒ Journal for Control, Measurement, Electronics, Computing and Communications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.