Abstract

ABSTRACTIn this study, the removal of arsenic was evaluated using micellar-enhanced ultrafiltration process. Response surface methodology and Box-Behnken matrix methods were also applied to design the experiments and determine the optimum conditions. Therefore, the main operational parameters including pH (4–10), initial concentration of arsenic (20–80 µg/L), and concentration of Cetyltrimethylammonium bromide (CTAB) (1–3 mM) were investigated. The results of analysis of variance revealed a good agreement between experimental data and the built model with the determination coefficient (R2) of 0.99. Accordingly, the removal efficiency obtained was about 94.8% at the optimal condition (pH = 6.73, the initial concentration of arsenic = 29.44 µg/L, and CTAB concentration of 2.83 mM).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.