Abstract
Effective signal processing technology should be used to improve signal-to-noise ratio in air-coupled ultrasonic testing,because of feeble signal and low signal-to-noise ratio.Pulse compression with non-linear frequency modulation is applied in air-coupled ultrasonic testing,based on the research of pulse compression with linear frequency modulation,some improved method are presented.Principle of non-linear frequency modulation pulse compression is introduced.The effect of frequency characteristic of transducers is analyzed,because of the particularity of ultrasonic testing process.The affecting of stimulating mode to ultrasonic signal and pulse compression to signal-to-noise ratio are researched by comparing experiment results.The imaging testing experiment of fiberglass composite sample is accomplished with air-coupled ultrasonic C-scan testing system.Experiment results indicated that the pulse compression with non-linear frequency modulation is effective to improve the effect of pulse compression,and enhance the effect of air-coupled ultrasonic testing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.