Abstract

Effective signal processing technology should be used to improve signal-to-noise ratio in air-coupled ultrasonic testing, because of there is feeble signal and low signal-to-noise ratio. Pulse compression of linear frequency modulation could enhance system's signal to noise ratio and distance resolution effectively. Principle of linear frequency modulation pulse compression is introduced, including of designing and accomplishing of matching filter. The relationship between pulse compression parameters and testing result is analyzed. The affect of exciting mode to ultrasonic signal and pulse compression to signal-to-noise ratio are researched by comparing experiment results. Air-coupled ultrasonic C-scan testing system based on pulse compression is accomplished, and the effectiveness of pulse compression method is testified by ultrasonic imaging results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.