Abstract
Characteristics of ultrafiltration membranes with respect to the removal of nanoscale particles can be determined by surrogate challenge tests (SCTs). Key elements of a successful SCT are the selection of a suitable surrogate and a reliable quantification method. A major challenge when using nanoparticles as surrogates is their quantification in the filtrate, since commonly used particle detection methods are often lacking in sensitivity. The applicability of laser-induced breakdown-detection (LIBD) as a monitoring tool for SCTs has therefore been evaluated. The SCTs were carried out using polystyrene (PS) and silicate particles spiked into ultrapure water and into bank filtrate. Nanoparticles were detectable down to 10 nm and, depending on the material, down to a few ng/L. The nominal pore-size of the ultrafiltration membrane could be confirmed during the tests, demonstrating the suitability of LIBD as a highly sensitive monitoring technique for SCTs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.