Abstract
Fluid dynamic gauging (FDG) is a non-contact technique for measuring the thickness and strength of fouling layers immersed in liquid in situ. Its application to an annular geometry across a range of possible flow conditions, from stagnant to turbulent flow regimes (annulus Reynolds number ∼29,000), is demonstrated. Two modes of measurement are demonstrated: in the first, the pressure drop across the nozzle is fixed and the mass flow rate of liquid withdrawn through the gauge is measured. In the second, the mass flow rate of liquid is fixed and the pressure drop measured: the latter is a new mode of measurement and it is shown to perform equally well, with advantages for particular applications. The results were not affected significantly by the surface under study being heated, indicating that the technique is suitable for measuring deposit thicknesses in situ during fouling and cleaning experiments in annular devices which are commonly used in deposition studies. Computational fluid dynamics (CFD) simulations, which afford detailed information about the flow patterns and shear stresses imposed on the surface, showed good agreement with experimental data for tests in the laminar regime: simulation of the transitional and turbulent regimes was not attempted. A short study of whey protein fouling recorded mixed success owing to the softness of the deposit, but demonstrated the scope for FDG to monitor the development of fouling layers in these geometries.
Accepted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have