Abstract

The power flow harmonic responses of the upper roll system are obtained by combining the speed solution and stress solution, and compare with the traditional harmonic response, we find that the traditional vibration displacement, velocity and acceleration harmonic response spectrum can’t completely reflect the reality of the vibration energy. The power flow vectors of the mill can be obtained with a color vector program developed independently. Compared with the vibration displacement vectors, we found that the displacement vector distribution of the mill is quite different from that of the power flow vector with the frequency of 104Hz: the displacement vector amplitude gradually increases from the bottom to the top of the mill, and the displacement vector is transmitted from bottom to top vertically. The power flow vector amplitude of the working roll and the intermediate roll is larger than that of the other parts, and power flow vectors present complex transfer directions. Similarly, when the considering frequency is taken as other values, the distribution of vibration displacement vector and power flow vector are also variable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.