Abstract
Large area metal-insulator-metal (MIM) structures are prone to exhibit weak electrical regions when they are subjected to severe stress conditions. Although the root cause of this problem is hard to identify, it has been attributed to non-uniform oxide thickness, variable dielectric permittivity, correlated defect generation, and fringe effects in capacitors. In this paper, we explore the application of artificial neural networks (ANNs) to the spatial localization of such weak regions. To this end, HfO2-based MIM structures were electrically stressed with the objective of generating a large number of breakdown spots. These spots are statistically distributed both in size and location over the device area. Two-input/two-output ANNs with different number of neurons and hidden layers were assessed with the purpose of identifying the best and simplest option for detecting where the most severe damage occurs. The obtained results are compatible with previous studies based on spatial statistics techniques. The method can be applied to other systems that exhibit multiple localized failure events.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.