Abstract

Background: The success of rotator cuff repair is primarily dependent on tendon-bone healing. Failure is common because weak scar tissue replaces the native enthesis, rendering it prone to reruptures. A demineralized bone matrix (DBM) consists of a network of collagen fibers that provide a sustained release of growth factors such as bone morphogenetic proteins. Previous studies have demonstrated that it can regenerate a fibrocartilaginous enthesis. Hypothesis: The use of a DBM and mesenchymal stem cells (MSCs) at the healing enthesis will result in a higher bone mineral density at the tendon insertion and will enhance the regeneration of a morphologically superior enthesis when compared with an acellular human dermal matrix. Study Design: Controlled laboratory study. Methods: Eighteen female Wistar rats underwent unilateral detachment of the supraspinatus tendon. Three weeks later, tendon repair was carried out in animals randomized into 3 groups: group 1 received augmentation of the repair with a cortical allogenic DBM (n = 6); group 2 received augmentation with a nonmeshed, ultrathick, acellular human dermal matrix (n = 6); and group 3 underwent tendon-bone repair without a scaffold (n = 6). All animals received 1 × 106 MSCs delivered in fibrin glue to the repair site. Specimens were retrieved at 6 weeks postoperatively for histological analysis and the evaluation of bone mineral density. Results: All groups demonstrated closure of the tendon-bone gap with a fibrocartilaginous enthesis. Although there were no significant differences in the enthesis maturation and modified Movin scores, repair augmented with a dermal matrix + MSCs exhibited a disorganized enthesis, abnormal collagen fiber arrangement, and greater cellularity compared with other MSC groups. Only repairs augmented with a DBM + MSCs reached a bone mineral density not significantly lower than nonoperated controls. Conclusion: A DBM enhanced with MSCs can augment rotator cuff healing at 6 weeks and restore bone mineral density at the enthesis to its preinjury levels. Clinical Relevance: Biological augmentation of rotator cuff repair with a DBM and MSCs may reduce the incidence of retears, although further studies are required to determine its effectiveness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.