Abstract
A model of the partial discharges in a sample of solid insulation with air cavity is presented. The material of the insulation is cross-linked polyethylene. The model is based on an active-capacitive equivalent circuit, in which the resistance of the air cavity at the instant of a partial discharge ignition is shunted by the active resistance of the spark. The model takes into consideration the delay of the discharge development. The evaluation of the diagnostic value of the apparent and true charges is carried out. The results of the apparent and true charges relationship with the dimensions and proportions of the air cavity are presented. It is shown that the same magnitude of both true and apparent charges can correspond to the different volumes and shapes of the air cavities in the insulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Известия высших учебных заведений. Электромеханика
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.