Abstract

A system for determining the dc resistance of individual conductors 2 /spl mu/m in diameter and 0.5-1 mm in length is described. The system uses a four-wire measurement, computerized data acquisition, and unique sample handling and contacting methods. To demonstrate system operation, data from measurements made on small-diameter copper wires are presented. These wires were first measured in long lengths on another system and then cut into short lengths and remeasured on this system. The results from these two measurement systems shown that this system is an effective tool for determining the resistance per unit length of short, small-diameter conductors. >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.