Abstract
Abstract Seepage control plays an important role in the design of pumped storage power station. In this paper, the seepage characteristics and geological conditions of the upper reservoir of a pumped storage power station are analyzed, and the natural seepage of the upper reservoir is calculated. According to the characteristics and amount of leakage, the upper reservoir can be controlled by local seepage control scheme, and the anti-seepage treatment scheme of the south reservoir bank is compared and analyzed. After the local anti-seepage treatment of upper reservoir, the daily seepage volume decreased from 5585m3/d to 2304m3/d, which indicates that the selected anti-seepage scheme is suitable. This paper can provide useful reference for similar projects in the future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.