Abstract

A flow through electrochemical cell was designed for the implementation of a simple, efficient, rapid and sensitive method for determination of mercury in water samples by anodic stripping voltammetry. A solid gold or a gold film electrode can be used as working electrode in a wall-jet configuration of the cell. The analyte is electrolyzed on the electrode surface by pumping the liquid sample through a continuous flow manifold at a flow rate of 8 mL/min. Deposition efficiency increased by increasing the velocity at which the sample arrives to the cell. After deposition of the analyte, it was stripped from the electrode by using a linear anodic potential scan at 35 mV/s. Geometric and hydrodynamic variables of the system were studied in order to optimize the analytical response. A detection limit of 0.05 ng/mL was reached by using a preconcentration time of 540 s. The repeatability expressed as relative standard deviation was always less than 3%. The method shows a good selectively and was successfully applied to the determination of mercury in different water samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.