Abstract
The anodic polarographic behavior of ciclopirox have been studied in Britton Robinson buffer (BRb) over the pH range 6–11. In BRb of pH 7 a well defined anodic wave was produced with diffusion current constant (Id) of 4.86±0.048 (n=6) using DC t mode. Adopting both of direct current (DC t) and differential pulse polarographic (DPP) modes, the current-concentration relationship was found to be rectilinear over the range 4 to 24 and 2 to 12 μg ml −1 respectively, with minimum detectability (S/N=2) of 0.2 μg ml −1 (1×10 −6 M) using the DPP mode. The average percent recovery was favourably compared to a reference method, with a satisfactory standard deviation, the proposed method was further applied to the determination of ciclopirox olamine in certain pharmaceutical preparations including lotion and cream. The average percentage recoveries for lotion were 100.06±0.94 and 100.06±1.08 using DC t and DPP modes respectively, and for cream were 100.17±0.64 and 100.34±1.28 using DC t and DPP modes, respectively. A pathway for the electrode reaction was postulated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.