Abstract
Conventionally, the radius of curvature of crystal planes in a wafer is measured by position-dependent X-ray diffraction (XRD) along a particular diagonal direction of the wafer. However, we show herein that this method is not reliable for assessing the wafer’s real three-dimensional curvature. Using commercial 2 inch 4H-SiC, GaN, AlN, and β-Ga2O3 wafers, we demonstrate that the choice of the diagonal direction along which the position-dependent XRD was acquired strongly affects not only the apparent radius of curvature but also whether it is convex or concave.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.