Abstract
Angular distribution of C2+ ions produced in C4+(1s2) + He → C2+(1s22s2) + He2+ at collision energy of 270 and 470 eV are presented. Measurements have been carried out with an experimental setup for the state selective differential cross section measurements of electron capture processes which utilizes the 14.5 GHz Caprice Electron Cyclotron Resonance (ECR) ion source at RIKEN. It is found that results of calculations based on the potential, which was obtained from the previous experimental results at 1520 eV, do not reproduce the present experimental results at 270 and 470 eV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.