Generally, L anchor bolt system has been used for a long period of time in construction industry as one of the distributing load structures. However, there are some weaknesses in L anchor bolt which may straighten and pullup when charged with tensile load. Current practices prefer to use other types of anchor bolt systems, such as headed studs anchor bolt system to replace the L anchor bolt design. There has been lack of studies to prove that it is more effective in terms of performance. A new T anchor bolt which was basically modified from headed studs anchor bolt was proposed in this study to compare its performance of tensile loading in concrete failure to typical L design. This study aims to determine whether the T anchor bolt system gives better performance as compared to an L anchor bolt system. The performance was rated based on tensile loading on concrete failure pattern. A pullout test was conducted on two different anchor bolt systems, namely L and T. The anchor bolt embedded depth, h in concrete were varied according to their hook or bend radius. Each sample was repeated twice. There were totally eight samples. The hook or bend radius used were 50 mm and 57.5 mm for sample L1 and L2, respectively. 90-degree bend were used on sample T1 and T2. Based on test results, it can be seen that the performance of concrete failure pattern under tensile load on both L and T anchor bolt design samples with 200 mm embedment depth was better than deeper embedment depth of 230 mm. But the L anchor bolt design gives the best results as compared to T design. Although T anchor bolt design shows higher resistance before first bond failure to the concrete sample. T anchor bolt was analysed and needed deeper embedment depth to allow formation of cone pull-out shape to acquire better performance.
Highlights
L anchor bolt system has been used for a long period of time in construction industry as one of the distributing load structures
The structure resist from failure by frictional bond of the concrete cone and the anchor bolt until ultimate tensile load was reached
The highest tensile load failure occurred at sample L2B at 12.583 kN, while the lowest tensile load reading before failure occurred at L2A at 10.625 kN
Summary
L anchor bolt system has been used for a long period of time in construction industry as one of the distributing load structures. A new T anchor bolt which was basically modified from headed studs anchor bolt was proposed in this study to compare its performance of tensile loading in concrete failure to typical L design. It can be seen that the performance of concrete failure pattern under tensile load on both L and T anchor bolt design samples with 200 mm embedment depth was better than deeper embedment depth of 230 mm. There have been a few studies carried out for T anchor bolt to prove that it performs better on tensile loading and in concrete failure as compared to J anchor bolt system. This study aims to design a new anchor bolt that produces better performance on tensile load. The anchor bolt that has been used are “T” shaped anchor bolt that cast in-situ for 4 samples and “L”
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.