Abstract
The determination of urinary 3-phenoxybenzoic acid enables exposure to pyrethroid insecticides to be evaluated. A method for the quantitative determination of this metabolite in urine is described. The compound and the internal standard (2-phenoxybenzoic acid) are derivatized with pentafluorobenzylbromide and transformed into pentafluorobenzyl esters, which are determined by gas chromatography with an intermediate polarity capillary column and an electron-capture detector. Before GC analysis, the urinary extracts are purified on LC-Si SPE columns. The proposed method has a detection limit of 0.5 μg/l and a mean recovery of 91.3%. The coefficient of variation of the analytical procedure, evaluated at a concentration of 24.96 μg/l, was 9.58%. Storage of the urine samples for 3 months at −18°C did not lead to significant changes in the concentration of analyte. The method was tested analysing the urine of a farm worker with symptoms of pyrethroid poisoning, occupationally exposed to esfenvalerate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.