Abstract

In this paper, we evaluated the effect of seven stabilizers with different shapes (including cylinder, cubic and ball shape) on zircon U–Pb dating analysis by laser ablation inductively coupled plasma quadrupole mass spectrometry (LA-ICP-QMS) in detail. In the case of stabilizer volume examined, the analytical efficiency of cylinder stabilizers (21.2, 25.1, 35.3 and 125 mL) were investigated in terms of signal stabilization, signal rising/washout time and U–Pb dating accuracy. By using zircon 91500 as reference material for external calibration, the 206Pb/238U age of zircon Plešovice was determined by a nanosecond LA-ICP-QMS, where the stabilizer was placed directly after the ablation cell and sample aerosols carried by helium passed through the stabilizer and subsequently mixed with make-up gas (argon) before ICP. It was found that transient signal oscillations were invisible and signal intensities were comparable using all the stabilizers, while signal rising time was 2.0-fold and washout time was 27.6-fold for stabilizer with volume of 125 mL to that of 21.2 mL. The obtained average 206Pb/238U age of zircon Plešovice was 335.53 ± 1.02, 361.73 ± 5.04, 340.10 ± 1.98 and 341.21 ± 5.17 Ma (2σ, n ≥ 5), respectively, giving average relative deviations of a single point of age (1σ) less than 2.0%. Among the corresponding 206Pb/238U ratios, it was also found that the value (0.05343 ± 0.87‰, 1σ, n = 5) obtained using 21.2 mL of cylinder stabilizer highly agreed with that of 0.05384 ± 0.74‰ (1σ, n = 5) using the commercially available “squid” stabilizer. The analytical efficiency of the 21.2 mL of cylinder stabilizer was then compared to that of cubic shape stabilizer (18.5 mL) and ball shape stabilizer (14.1 mL). Results showed that there were no significant differences of the obtained 206Pb/238U ages using stabilizers with volume in the range of 14.1–21.2 mL. But both cubic and ball shape stabilizers exhibited washout time over 270 s. We also studied the particle filter effect of the stabilizers by packing the 21.2 mL of cylinder stabilizer with 1.0 g of stainless wire. Despite the average 206Pb/238U age deviation was only − 0.81%, spiky signals occasionally occurred which might be ascribed to the use of a nanosecond laser and relatively low density of stainless wire in the stabilizer. This study confirmed that an empty stabilizer with volume of 21.2 mL and cylinder shape was preferred to produce smoothing signals. The improved analytical accuracy of zircon U–Pb dating using such a stabilizer ensured the future application to trace element analysis by LA-ICP-QMS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.