Abstract
The reversed-phase high-performance liquid chromatography with electrochemical detection was used to quantify plasma and urine levels of vinblastine, vincristine, vindesine and a metabolite of vinblastine, desacetylvinblastine. Sample clean-up consisted of solid-phase extraction with a Bond Elut CN column. The extracts were separated on a Hypersil ODS column. The mobile phase consisted of a mixture of methanol and 10 m M phosphate buffer (pH 7.0). The limit of sensitivity using electrochemical detection was 100 pg on-column for all compounds with a signal-to-noise ratio of 3. Quantification of the compounds in human plasma and urine was possible down to 1 ng/ml (ca. 1 pmol). Pharmacokinetic results show that the sensitivity of the method is adequate for drug monitoring in clinical research.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.