Abstract

A contribution to the understanding of total dose degradation using both AC small signal analysis and DC analysis in linear bipolar circuits is proposed. The reasoning is illustrated step by step on the basis of experimental results obtained on the LM 139. It is shown that the input stage is mostly responsible for the degradation up to 20 krad. Above 20 krad, the total degradation is due to a combination of the input and the output stage degradation. The amplifier stage does not play a significant role in the circuit degradation

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.