Abstract

The radiation showers generated by the interaction of high-energy electrons with matter include neutrons with an energy distribution peaked at the MeV scale, produced via photonuclear reactions, allowing measurements of neutron-induced Single-Event Effects in electronic devices. In this work we study a setup where the 200-MeV electron beam of the CLEAR accelerator at CERN is directed on an aluminum target to produce a radiation field with a large neutron component. The resulting environment is analyzed by measuring the Single-Event Upset (SEU) and Latchup rates in well-characterized SRAMs, as well as the Total Ionizing Dose in passive Radio-Photo-Luminescence dosimeters, and by comparing the results with predictions from FLUKA simulations. We find that a lateral shielding made of lead protects the SRAMs from an excessive TID rate, yielding an optimal configuration for SEU measurements, particularly in SRAMs that are highly sensitive to MeV-scale neutrons. This setup provides an interesting complementary neutron source with respect to standard neutron facilities based on spallation targets or radioactive sources.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call