Abstract

In order to obtain the pressure drop of the horizontal liquid-solid circulation fluidization bed with Kenics static mixers, experiments were carried out in four Kenics static mixers with different aspect ratio of mixing element(AR) over a range of 30000 to 51000 to get pressure drop data. Dimension analysis revealed that the pressure drop characteristic of the Kenics static mixer can be described by three dimensionless parameters, such as the friction factor, Reynolds number, and aspect ratio of mixing element. According to the experiment data, a new dimensionless pressure drop correlation was developed. The results indicate that the value of Cf becomes constant and has no correlation with the value of Re in fixed AR. The value of Cf was increased with the increase of AR.