Abstract
This paper considers the method of assessing the impact of volume-planning solutions of a residential building on the thermal power of the heating system. The method is based on the study of the model of the estimated power of the heating system (taking into account the thermal power of the vent air heating), which represents a system of dependencies, including both the size of the building (heated volume), so the thermal characteristics of the external fencing structures (regulatory resistance of heat transmission), in the form of universal functional dependence on the basic parameters of the outer climate (estimated temperature for the design of the heating period) for the region. The results of the analysis of changes in the estimated power of the heating system from the characteristics of the building: the ratio of the size of the sides of the building in the plan, the height (floor) of the building, the area of glazing vertical fences are presented.