Abstract
This paper focuses on the degradation at the wire bond contact with the metalized pad, and precisely its evolution with the power module aging. In order to induce damage in this particular zone, an accelerated power cycling test is carried out on well-suited devices. The on-state voltage (VCE) is measured during the test as an indicator of the degradation in the wire and metallization. Then, analyses of the interface wire-metallization are done with a numerical microscope and the EBSD (Electron Back-Scattered Diffraction) technique. As a result, an attempt to correlate the evolution of the degradation with the changes in the granular microstructure of the aluminium constituting the wire and metallization is proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.