Abstract
This paper analyzes the characteristics of the inter-turn short circuit fault based on the permanent magnet synchronous motor (PMSM) structure algorithm. The finite element model of the PMSM inter-turn short circuit fault is established for the electric vehicle application. Simulations are performed on healthy motor and faulty motor with different severity of short circuit faults and operate modes. Then analyzes the influences of short circuit fault on the magnetic field and various parameters of motors and extracts feature vector for detecting inter-turn short circuit fault. It also proves that the method of finite element analysis (FEA) can provide a scientific and accurate basis for studying on inter-turn short circuit fault. This research method makes a foundation for diagnosis of other faults of PMSM for electric vehicle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.