Abstract

This paper analyses corona discharge in ambient air flow associated with laboratory-scaled wire-to-plate electrostatic precipitator (WPESP). The corona discharge is analysed by a combined iterative computational technique based on the finite element method (FEM) and charge simulation method (CSM). The phenomenon is mathematically described by Maxwell's equations in differential form. A finite element method is used to solve the Poisson's equation and the charge simulation method is used to satisfy the current continuity condition. Measurement method of the positive dc corona current density and electric field, taking into account the air flow velocity, has been introduced. The computed results are compared with experimental results to test the effectiveness of this approach.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.