Abstract

This paper aims at analysis of the monopolar ionized field in an Electrostatic Precipitator (ESP). The corona parameters are analyzed by a combined iterative computational technique based on the Finite Element Method (FEM) and Charge Simulation Method (CSM). We proposed the introduction of a potential corresponding to the critical minimum ionization field directly in the finite element formulation as a Dirichlet condition. The computational model is validated by a comparison with experimental measurements of current density and electric field and with data from the electrostatic precipitator literature on a simple system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have