Abstract
A feasible and reproducible method for multiresidue analysis of several common pesticides, of different polarities, in wine samples is proposed. The method combines a solid-phase extraction on polymeric cartridges eluted with ethyl acetate and a gas chromatographic determination using electron capture and nitrogen–phosphorus detection. To avoid the matrix effect, previous washing of the cartridges with a mixture of water–2-propanol (90:10) and further clean-up of the extract on Florisil cartridges, together with a calibration using spiked extracts, are recommended.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.