Abstract

To assess the feasibility of the 31% Pu-MOX fuel rod design of reduced-moderation water reactor (RMWR) in terms of thermal and mechanical behaviors, a single rod assumed to be irradiated in the core of RMWR up to 106 GWd/tHM has been analyzed by a fuel performance code FEMAXI-RM which is an extended version of FEMAXI-6 code. In the analysis, design specifications of fuel rod and irradiation conditions have been input, and available models of both MOX fuel and UO 2 fuel have been used as appropriate. The results are: fission gas release is several tens of percent, rod internal pressure does not exceed the coolant pressure, and the highest fuel center temperature is 2400 K, while cladding diameter increase caused by pellet swelling is within 1% strain. These predictions suggest that the MOX fuel rod integrity will be held during irradiation in RMWR, though actual behavior of MOX pellet swelling and cladding oxidation require to be investigated in detail.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.