Abstract

ABSTRACT In this research, a combined system consisting of a supercritical CO2 Brayton cycle and an ejector-expansion refrigeration cycle with dual evaporators is presented with the aim to harness the engine exhaust heat effectively. Cascade ejectors are adopted to further reduce the destruction caused by the isenthalpic expansion process, which also can be considered as pressure recovery process. Comparative analysis in terms of thermodynamic and economic is performed between the previously reported system and the modified system under the combined power, refrigeration, and freezing mode (mode 1) and combined refrigeration and freezing mode (mode 2). It is found that improvements of 0.57% and 10.22% in exergy efficiency under mode 1 and mode 2 were achieved by the modified system, respectively, and the sum unit cost of product is reduced by 7.72% compared to the basic system. In the optimized condition, cooling capacities of 18.79 kW and 33.80 kW can be provided for refrigerated zone and freezing zone, respectively. And the exergy efficiency and sum unit cost of product of the system are 16.95% and 108.64 $/GJ, respectively, with a dynamic payback period of 4.994 years.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.