Abstract

The infrared temperature measurement technique has been applied in various fields with the development of charge coupled device. In the problem of metal surface temperature measurement, if the surface is covered by participating media, the traditional infrared temperature measurement technique will lead to intolerable measurement errors. In this work, the infrared temperature measurement problem was solved by the source multi-flux method. On this base, the impact of the flue gas thickness and surface temperature on the apparent temperature measured by the charge coupled device was analyzed. Furthermore, the corresponding experimental system was set up. And the experimental results were found to have a good agreement with the simulated results. Finally, the idea of modification for the infrared temperature measurement by inverse method was proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.