Abstract

The research is supported by a Project Funded by the brand professional project form Yancheng teachers college (2016) and the teaching reform and practice of medicinal chemistry (2018YCTUJGY006) and the innovation and entrepreneurship training program for college students in jiangsu province ( 201910324016Z ) Abstract The content of ammonia nitrogen in water was determined by national standard method - nessler's reagent spectrophotometry. Through comparison, it was found that the method of reagent configuration, the amount of reagent, the detection wavelength, the color development time and the temperature had an impact on the analysis results in the ammonia nitrogen measurement in water by the reagent spectrophotometry. Based on the experimental results, the factors influencing the determination of ammonia nitrogen by spectrophotometry with nessler's reagent were discussed. Keywords Nessler's reagent spectrophotometry, Ammonia nitrogen, Influencing factors, Blank value, ABS value, Correlation coefficient. DOI : 10.7176/JEP/10-31-08 Publication date: November 30 th 2019

Highlights

  • Ammonia nitrogen in aqueous solution is nitrogen in the form of free ammoniaor ionic ammonia (NH4+)

  • The commonly used method for the determination of ammonia nitrogen in environmental monitoring laboratories in China is nessler's reagent spectrophotometry, which has the characteristics of simplicity, rapidity, economy and high benefit

  • In this paper, the blank value, Abs value and correlation coefficient of the reagent photometry were analyzed, and the optimal conditions were determined through comprehensive consideration, so as to achieve the optimal expected effect

Read more

Summary

Introduction

Ammonia nitrogen in aqueous solution is nitrogen in the form of free ammonia (or non-ionic ammonia, NH3)or ionic ammonia (NH4+). Especially fish, are sensitive to non-ionic ammonia. To protect freshwater aquatic organisms, the concentration of non-ionic ammonia in water should be less than 0.02 mg L-1. The commonly used method for the determination of ammonia nitrogen in environmental monitoring laboratories in China is nessler's reagent spectrophotometry, which has the characteristics of simplicity, rapidity, economy and high benefit. In actual operation, factors such as reagent allocation method, reagent dosage and temperature will affect the blank value, Abs value and correlation coefficient of ammonia nitrogen measurement. In this paper, the blank value, Abs value and correlation coefficient of the reagent photometry were analyzed, and the optimal conditions were determined through comprehensive consideration, so as to achieve the optimal expected effect

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.